Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Rev. bras. ortop ; 58(1): 9-18, Jan.-Feb. 2023. graf
Article in English | LILACS | ID: biblio-1441347

ABSTRACT

Abstract Axial axis metastasis remains a challenge for surgical as well as other treatment modalities, like chemotherapy, immunotherapy, and radiotherapy. It is unequivocal that surgery provides pain improvements and preservation of neurological status, but this condition remains when associated with radiotherapy and other treatment modalities. In this review, we emphasize the current forms of surgical treatment in the different regions of the spine and pelvis. The evident possibility of percutaneous treatments is related to early or late cases, and in cases in which there are greater risks and instability to conventional surgeries associated with radiotherapy and have been shown to be the appropriate option for local control of metastatic disease.


Resumo As metástases no eixo axial permanecem um desafio para o tratamento cirúrgico bem como para outras modalidades, como quimioterapia, imunoterapia e radioterapia. É inequívoco que a cirurgia proporciona melhorias na dor e na preservação do status neurológico; porém, há permanência desta condição quando associada à radioterapia e a outras modalidades de tratamento. Nesta revisão damos ênfase às formas de tratamento cirúrgico atuais nas diferentes regiões da coluna vertebral e pelve. A evidente possibilidade de tratamentos percutâneos está relacionada a casos iniciais ou tardios, bem como a casos em que há maiores riscos e instabilidade às cirurgias convencionais associadas à radioterapia, e tem se mostrado a opção adequada para o controle local da doença metastática.


Subject(s)
Humans , Pelvis/surgery , Spine/surgery , Bone Neoplasms , Fractures, Spontaneous
2.
Rev. bras. ortop ; 49(5): 494-498, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-727690

ABSTRACT

Objective: To study the anatomy of the posterior cruciate ligament (PCL) and define anatomical parameters with the knee flexed at 90°. Methods: Eight knees from cadavers were dissected in order to make measurements from the center of the anterolateral band to the roof (AL1), from the center of the anterolateral band to the anterior cartilage (AL2), from the center of the posteromedial band to the roof (PM1), from the center of the posteromedial band to the anterior cartilage (PM2), from the center of the tibial insertion to the medial region of the tibia (TIM), from the center of the tibial insertion to the lateral region of the tibia (TIL), from the center of the medial insertion to the medial meniscus (IMM) and the width of the origin of the PCL (WO). To obtain the results from each anatomical structure, the means and standard deviations of the measurements were calculated. Results: The measurements in millimeters that were found were AL1, 6.2; AL2, 4.9; PM1, 11.7; PM2, 5.5; TIM, 32.5; TIL, 40.6; IMM, 9.4; and WO, 32.5. Conclusions: The PCL has an extensive origin. The center of the anterolateral band is 6 mm from the roof and 5 mm from the anterior cartilage of the knee. The tibial insertion is slightly medial and 10 mm distal to the posterior cornu of the medial meniscus...


Objetivo: Estudar a anatomia do ligamento cruzado posterior (LCP) e definir parâmetros anatômicos com o joelho em 90° de flexão. Métodos: Oito joelhos de cadáveres foram dissecados para tirar as medidas do centro da banda anterolateral ao teto (AL1), do centro da banda anterolateral à cartilagem anterior (AL2), do centro da banda posteromedial ao teto (PM1), do centro da banda posteromedial à cartilagem anterior (PM2), do centro da inserção tibial à região medial da tíbia (ITM), do centro da inserção tibial à região lateral da tíbia (ITL), do centro da inserção medial ao menisco medial (IMM) e da largura da origem do LCP (LO). Para a obtenção dos resultados de cada estrutura anatômica foram calculados os valores de média e desvio padrão das medições. Resultados: As medidas, em milímetros, encontradas foram AL1, 6,2; AL2, 4,9; PM1, 11,7; PM2, 5,5; ITM, 32,5; ITL, 40,6; IMM, 9,4; e LO, 32,5. Conclusões: o LCP tem uma origem extensa. O centro da banda anterolateral fica a 6 mm do teto e a 5 mm da cartilagem anterior do joelho. A inserção tibial fica levemente medial e 10 mm distal ao corno posterior do menisco medial...


Subject(s)
Humans , Anatomy , Cadaver , Posterior Cruciate Ligament/anatomy & histology
3.
Rev. bras. ortop ; 48(5): 417-420, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697312

ABSTRACT

OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. .


OBJETIVO: Determinar parâmetros anatômicos para localizar a inserção dos tendões flexores do joelho na tíbia. MÉTODOS: Foram selecionados 10 joelhos de cadáveres com estruturas mediais e anteriores íntegras. A dissecção foi feita por acesso ânteromedial até a exposição adequada da inserção dos tendões flexores (TF), do planalto tibial (PT) e da tuberosidade anterior da tíbia (TAT). Uma agulha 40×12 e um paquímetro digital foram usados para aferir a distância do planalto tibial da inserção dos tendões flexores do joelho a 15 mm da borda medial ao tendão patelar e da tuberosidade anterior da tíbia à inserção dos tendões flexores do joelho. O ângulo o planalto tibial e a inserção dos tendões flexores do joelho (PT-TF) foi calculado com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância PT-TF foi de 41 ± 4,6 mm em média. A distância entre a TAT-TF foi de 6,88 ± 1 mm. A angulação (PT-TF) foi de 20,3 ± 4,9 graus. CONCLUSÃO: Na região anterior da tíbia os tendões flexores estão a cerca de 40 mm do planalto com um ângulo médio de 20 graus. .


Subject(s)
Humans , Anatomy , Cadaver , Knee/anatomy & histology
4.
Rev. bras. ortop ; 48(5): 402-405, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697320

ABSTRACT

OBJECTIVE: To study the anatomy of the oblique popliteal ligament, as regards its dimensions, expansion and anatomical relationships. METHODS: Eleven cadaver knees were dissected in order to study the anatomy and take mea-surements of anatomical structures and relationships of the oblique popliteal ligament. The dissection was for posterior access to the proper exposure of the oblique popliteal ligament, the semimembranosus muscle and its expansions. For measurement of dimensions, 40 × 12 needles were used for marking the specific points and a caliper. The angles were calculated using the software ImagePro Plus(r) . RESULTS: The distance from the origin of the oblique popliteal ligament to the tibial plateau was 7.4 mm, the thickness at its origin was 7.3 mm, length was 33.6 mm and the tibial plateau angle 34.8°. The length of the expansion of the proximal oblique popliteal ligament was 39.2 mm, thickness 7.8 mm and angle of the oblique popliteal ligament with its expansion 32.2°. CONCLUSION: The oblique popliteal ligament is thick, rises in the semimembranosus and protrudes proximally forming an acute angle with the joint interline, crossing the popliteal fossa. In some cases it has a proximal expansion. .


OBJETIVO: Estudar a anatomia do ligamento poplíteo oblíquo no que se refere às suas dimensões, expansões e relações anatômicas. MÉTODOS: Onze joelhos de cadáveres foram dissecados com o intuito de se estudar a anatomia e fazer medições das estruturas e das relações anatômicas do ligamento poplíteo oblíquo. A dissecção foi por acesso posterior até a exposição adequada do ligamento poplíteo oblíquo, do músculo semimembranoso e de suas expansões. Para aferição das medidas, foram usados agulhas 40x12 na marcação dos pontos específicos e um paquímetro. Os ângulos foram calculados com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância da origem do ligamento poplíteo oblíquo ao platô tibial foi de 7,4 mm, a espessura na sua origem foi de 7,3 mm, o comprimento foi de 33,6 mm e o ângulo com o platô tibial foi de 34,8°. O comprimento da expansão proximal do ligamento poplíteo oblíquo foi de 39,2 mm, a espessura foi de 7,8 mm e o ângulo do ligamento poplíteo oblíquo com sua expansão foi de 32,2°. CONCLUSÃO: O ligamento poplíteo oblíquo é espesso, nasce no músculo semimembranoso, projeta-se proximalmente, forma um ângulo agudo com a interlinha articular e cruza a fossa poplítea. Em alguns casos apresenta uma expansão proximal. .


Subject(s)
Anatomy , Cadaver , Knee
5.
Acta cir. bras ; 27(5): 283-288, May 2012. ilus, tab
Article in English | LILACS | ID: lil-626240

ABSTRACT

PURPOSE: To determine whether it is possible and the difficulty of anatomical placement of guide wires for reconstruction of the two bands of the anterior cruciate ligament using transtibial technique and to measure the angle and positioning of the anatomic tibial guide wires for this technique. METHODS: Ten cadaver knees were dissected and a guide wire was positioned in the center of origin and insertion of each band. Were collected measurements of the distance from: 1) the entry point of the guide wire on tibial tuberosity; 2) the medial end of the tibia; 3) the tibial articular surface. Were also measured the medial and caudal angles of the guide wires. RESULTS: For the anteromedial band the medial angle was 19±5º and the caudal was 44±4º.The distances were 20±2 mm from anterior tuberosity, 26±5 mm from the tibial plateau and 25±5 mm from the medial end of the tibia. For the posterolateral band the medial angle was 26±5º and the caudal one was 36±8°. The distances were 31±6 mm for the anterior tuberosity, 24±4 mm for the tibial plateau and 17±7 mm from the end of the tibia. CONCLUSIONS: It is possible to position the guide wires of the two bands to reconstruct the anterior cruciate ligament using transtibial technique. The parameters for the proper positioning of the guide wire from anteromedial band is caudal angle of 44º with entry point 20 mm from anterior tuberosity; for the posterolateral band the caudal angle is 36º; from the tibial tuberosity the distance is 31 mm. This technique is difficult to perform leaving its questionable reproducibility.


OBJETIVOS: Determinar se é possível o posicionamento anatômico dos fios-guia para reconstrução das duas bandas do ligamento cruzado anterior pela técnica transtibial, sua dificuldade técnica e medir o posicionamento angular dos parâmetros anatômicos dos fios-guia tibiais para esta técnica. MÉTODOS: Dez joelhos de cadáveres foram dissecados e um fio guia foi posicionado no centro da origem e inserção de cada banda. Foram coletadas as medidas da distância do ponto de entrada do fio-guia à tuberosidade anterior da tíbia, a extremidade medial da tíbia e a superfície articular tibial. Também foram medidos os ângulos mediais e caudais dos fios-guia. RESULTADOS: Para a banda anteromedial o ângulo medial foi de 19±5º e o caudal de 44±4º. As distâncias foram de 20±2 mm da tuberosidade anterior, 26±5 mm do platô tibial e 25±5 mm da extremidade medial da tíbia. Para a banda posterolateral o ângulo medial foi de 26±5° e o caudal de 36±8°. As distâncias foram de 31±6 mm da tuberosidade anterior, 24±4 mm do platô tibial e 17±7 mm da extremidade medial da tíbia. CONCLUSÕES: É possível posicionar os fios-guia para reconstrução das duas bandas do ligamento cruzado anterior pela técnica transtibial. Os parâmetros para o posicionamento adequado do fio-guia da banda anteromedial são ângulo caudal de 44° com ponto de entrada a 20 mm da tuberosidade anterior; para a banda posterolateral o ângulo caudal é de 36° e a distância é de 31 mm da tuberosidade anterior da tíbia. Essa técnica é de difícil execução deixando sua reprodutibilidade questionável.


Subject(s)
Humans , Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament Reconstruction/instrumentation , Cadaver
6.
Rev. bras. ortop ; 31(3): 240-6, mar. 1996. tab
Article in Portuguese | LILACS | ID: lil-212499

ABSTRACT

Foram realizadas escanometrias em dois esqueletos humanos, simulando alteraçoes de posicionamento e erros técnicos; os exames foram medidos por três observadores diferentes. O objetivo foi verificar a influência dessas variáveis nas medidas escanométricas. Foi obtida a medida real dos fêmures e tíbias de ambos os esqueletos com um paquímetro. A medida real foi comparada a uma escanometria denominada "padrao" e os seus resultados como base para análise estatística das outras medidas. Diferentes variaçoes na altura e inclinaçao da ampola de raios X, e na posiçao articular, foram comparadas com o lado contralateral. Os resultados mostraram diferenças estatisticamente significativas em algumas variáveis que simulavam erros técnicos (ampola do RX centrada no grande trocanter e nas inclinaçoes da ampola a 15º céfalico, 5º caudal e 15º caudal). O mesmo ocorreu em certas escanometrias que simulavam deformidades em flexao do quadril e joelho. A experiência do observador também determinou diferenças estatisticamente significativas. A escanometria é um bom método para o acompanhamento de pacientes com dismetrias de membros inferiores. Contudo, cuidados devem ser tomados no posicionamento do paciente, bem como na sua realizaçao técnica.


Subject(s)
Humans , Femur , Technology, Radiologic/methods , Tibia , Cadaver
SELECTION OF CITATIONS
SEARCH DETAIL